Furnace Pilot Light in Las Vegas: Why Relighting Often Is Not the Fix

Last updated: October 24, 2026 · Published by Colton Air Conditioning, NV license 0092120

Short answer: Most Las Vegas gas furnaces have no standing pilot light. They use a hot-surface or spark ignitor, so a furnace that won't light usually has an ignitor, flame sensor, gas valve, or safety-switch problem, not a pilot to relight. If you smell gas, leave the house right away. Don't use light switches, thermostats, appliance controls or anything that could spark. Once you're outside, call 911 and Southwest Gas (877-860-6020). If there's no gas smell, check the thermostat, filter, and furnace switch, try one restart, and if it still won't light, leave it off and book a visit. Search “furnace pilot light” and you get advice written for old standing-pilot furnaces. Most residential gas furnaces in the Las Vegas Valley use electronic ignition — a hot-surface ignitor or intermittent spark — not a flame that burns all year. If your heater will not light, the problem is often the ignitor, flame sensor, gas valve, or a safety switch — not a pilot you are supposed to match with a lighter. Book online or call (702) 738-6976 to schedule.

Standing pilot vs electronic ignition

TypeWhat it looks likeCommon in valley homes?
Standing pilotSmall flame always on; relight instructions on a panelOlder equipment only
Hot-surface ignitorGlows orange/white, then gas opensVery common
Intermittent spark / intermittent pilotClicks, lights only when heat is calledCommon on some brands

If you open the cabinet and there is no pilot tube with a constant flame, do not invent one. Forcing gas while clicking a control is how people get a gas smell and a dangerous situation.

If you smell gas

  1. Do not light anything. Do not use a phone in the house if the smell is strong.
  2. Leave the house right away. Don't use light switches, thermostats, appliance controls or anything that could spark. Once you're outside, call 911 and Southwest Gas (877-860-6020).
  3. Do not return until they say it is safe.

That overrides every thermostat tip on this page.

Symptoms at a glance

SymptomLikely causeCheck yourself or call
Ignitor glows or clicks, burners never lightWorn ignitor, gas valve not opening, or gas to the furnace offCheck the gas valve handle is in line with the pipe, one restart, then call
Burners light, then go out in a few secondsDirty flame sensor — see furnace flame sensorCall
Draft fan runs, no glow or clickPressure switch, inducer, or control board — see furnace pressure switchCall
Furnace lights and runs, then shuts off earlyLimit switch from poor airflow — see furnace limit switchCheck yourself: replace filter. Call if it repeats
Blinking light, no heatLockout after failed triesNote the blink pattern and call
Older furnace with a standing pilot that keeps going outDirty pilot orifice or failed thermocoupleRelight only with manufacturer instructions and no gas smell; call if it won't stay lit
Smell of gasPossible gas leakLeave the house right away. Don't use light switches, thermostats, appliance controls or anything that could spark. Once you're outside, call 911 and Southwest Gas (877-860-6020).

Furnace won't ignite: which stage is failing?

Most furnaces built since the 1990s don't have a standing pilot. They light in a fixed order, and where the order stops tells a technician a lot:

  1. Thermostat calls for heat and the inducer fan starts (a small motor hum). No hum → power, the thermostat, or the control board. See thermostat not working.
  2. Pressure switch confirms the vent is clear. If the inducer runs but nothing else happens, the switch or venting is a common cause. See furnace pressure switch.
  3. Ignitor glows or sparks. No glow → often a cracked hot-surface ignitor.
  4. Gas valve opens and burners light.
  5. Flame sensor proves the flame. Lights then shuts off within seconds → see furnace flame sensor.

If you smell gas at any point: leave the house right away. Don't use light switches, thermostats, appliance controls or anything that could spark. Once you're outside, call 911 and Southwest Gas (877-860-6020). Safe to do: confirm the thermostat is set to Heat, the furnace switch (looks like a light switch) is on, the breaker isn't tripped, and the front panel is fully seated (a door switch stops the furnace if it isn't). Don't: hold the gas valve open, bypass switches, or keep resetting the furnace again and again. Repeated failed tries can lock the control out and hide the original fault code. If the steps above don't get it lit, see our furnace repair in Las Vegas page, then call and tell us which stage it stopped at.

Safe checks when there is no gas smell

  1. Thermostat on Heat, a few degrees above the room — thermostat not working.
  2. Furnace switch on (looks like a light switch on the cabinet).
  3. One breaker reset if tripped; if it trips again, leave it off.
  4. Filter not packed — a dirty filter can cause lockouts that feel like “no pilot.”
  5. Listen once: draft motor, then ignition try, then flame. If it tries and quits, stop — furnace short cycling and heater not working.

Do not keep holding a red relight button through multiple failed attempts. Do not spray starter fluid or use a propane torch on an electronic ignition furnace.

What usually failed when “the pilot is out”

On electronic ignition systems:

  • Hot-surface ignitor cracked or open
  • Flame sensor dirty (desert dust) so the board shuts the gas off
  • Pressure switch or inducer problem
  • Limit switch open from overheating
  • Control board not completing the sequence

On a true standing-pilot system (uncommon, but still out there):

  • Pilot orifice dirty or thermocouple failed
  • Still a diagnosis — not a reason to run unvented heat overnight

We do not publish a relight walkthrough for every brand. Wrong steps on the wrong furnace are unsafe. Related: furnace repair Las Vegas, no heat tonight: what to do before your visit, furnace smell burning, HVAC second opinion.

Ignitor clicks but won't light

On most electronic-ignition furnaces, a call for heat runs the same sequence every time. The draft inducer motor starts. A pressure switch confirms the venting is drawing. The ignitor glows or sparks. The gas valve opens, and a flame sensor confirms the burners lit. If you hear clicking or see a glow but never get flame, or get flame for only a few seconds, one step in that chain is failing.

Hot-surface vs spark ignitors

TypeWhat you noticeWhat "won't light" looks like
Hot-surface ignitorA small element glows bright orange/white for several secondsGlow, then nothing; or no glow at all
Spark / intermittent pilotRapid ticking or clicking at the burnerTicking with no flame, then the furnace gives up

A hot-surface ignitor is fragile. Never touch it, even when it is cool. Skin oil and light bumps can crack it.

Common causes

  • Gas not reaching the burners. The gas valve handle at the furnace is turned off, or the furnace's gas valve is not opening when it should.
  • Dirty flame sensor. The burners light, then shut off in a few seconds because the board cannot confirm flame. Desert dust is a common reason. See furnace flame sensor.
  • Cracked or worn ignitor. A hot-surface ignitor that no longer gets hot enough, or a spark that is not reaching the gas.
  • Pressure switch or inducer problem. If the draft motor runs but you never get a glow or click, the control may not be getting proof of venting, so it never tries to light. See furnace pressure switch.
  • Lockout after repeated tries. After several failed attempts, many controls stop trying and show a blinking light. Write down the blink pattern before you reset anything.

Safe checks (only with no gas smell)

  1. Thermostat on Heat, set a few degrees above room temperature.
  2. Furnace switch on. It looks like a light switch on or near the cabinet.
  3. Filter not packed. Replace it if it is gray or collapsed.
  4. Gas valve handle at the furnace in line with the pipe (open). If it is crosswise and you did not turn it, leave it and call.
  5. Power the furnace off and on once at its switch, then listen through one full try.

Then stop. Do not keep cycling power, hold a relight button, or try to light the burners by hand. If you smell gas at any point: leave the house right away. Don't use light switches, thermostats, appliance controls or anything that could spark. Once you're outside, call 911 and Southwest Gas (877-860-6020), and do not go back in until they say it is safe. A burning dust or oil smell when the furnace first runs is normal and can linger for a couple of days. The one smell that is never normal is gas: leave the house right away. Don't use light switches, thermostats, appliance controls or anything that could spark. Once you're outside, call 911 and Southwest Gas (877-860-6020).

When to stop and call

Call when the safe checks are done, there is no gas smell, and the furnace still clicks or glows without lighting, lights and then drops out, or shows a blinking lockout code. Tell us what you heard (click, glow, nothing), the blink pattern, and what you already tried. In central Las Vegas? See our heating repair in 89102 page. On the southwest side of the valley, see our Enterprise page.

When to call

Call when Heat is set, power is on, there is no gas smell, and the furnace will not light or keep flame, or you are not sure whether you even have a standing pilot. Have ready if you can: about how old the furnace is, whether you hear clicking or see a glow, and whether anyone smelled gas (if yes, you should already be outside). If there is no gas emergency, finish the safe checks above and call us. We're open 24 hours, 7 days.

FAQ

Do Las Vegas furnaces still have pilot lights?

Some old ones do. Most modern installations use electronic ignition with no standing pilot.

Can I relight it myself?

Only on a furnace that is clearly a standing-pilot design with the manufacturer’s relight instructions on the cabinet, and only with no gas smell. If you are unsure, do not.

The furnace clicks but never lights. Pilot?

Usually an electronic ignition sequence failing — ignitor, sensor, or gas valve — not a match-and-relight job.

How do I schedule with Colton?

Book online or call (702) 738-6976 to schedule.

My furnace clicks but won't ignite. Is it the ignitor?

Sometimes. Clicking can be the relay or the gas valve trying. If the ignitor doesn't glow, it's a likely cause. If it glows and the burners don't light, the gas valve or gas supply is more likely. A technician can check each step.


No light after the safe checks, and no gas smell?

Book Online

Tell us what you heard (click, glow, nothing) and what you already tried. We will tell you if we can see it. Colton Air Conditioning · Las Vegas Valley residential HVAC

Book Online

License 0092120. If we have already been out, leave a Google review.